SOLITAX sc High Range Suspended Solids and Turbidity Analyzer for Immersion in Open Tanks
Product #: 6940200

OBSOLETE ITEM

Accurate, Color-independent Measurement

Primary and active sludge with different structures and colors, dark digested sludge and light lime sludge make the highest demands on the precise measurement of solids. Only SOLITAX sc solids probes with the patented dual scattered light method can satisfy these demands.

Self-cleaning Wiper Prevents Erroneous Values

The SOLITAX sc sensor's self-cleaning wiper prevents erroneous values and maintenance problems by preventing biological growth. Gas bubbles in the sample do not interfere with the measurement.

Easy One-point Calibration

All SOLITAX sc probes are factory calibrated in conformity with DIN EN ISO 7027 for long-term calibration stability. Calibration is not necessary. If the probe is used to measure the solids content, a one-point calibration suffices. Multipoint calibration is available for nonlinear samples.

Improve overall efficiency of the plant

Any two SOLITAX sc sensors can be installed using one HACH sc200 Controller. Helps improve process control and reduce treatment costs associated with polymer use, digester volume, and sludge handling.

Any two SOLITAX sc sensors can be installed using one Hach sc100 Controller

What's included?

Solitax hs-line sensor, Solitax User Manual, sc100 Controller, sc100 User Manual

Specifications

Accuracy: Turbidity: Defined according to ISO/WD 13530. Suspended Solids of reading or ±0.001 NTU, whichever is greater
Accuracy 2: Defined according to ISO/WD 13530.Turbidity Suspended Solids Less than 5 % of reading (depends on homogeneity of municipal activated sludge)
Cable Length: 10 m (33 ft.) standard. Optional extension cables available in 7.6 m (25 ft.), 15.2 m (50 ft.), 30.5 m (100 ft.). Maximum total length: (328 ft.).
Calibration: Turbidity Suspended Solids:Formazin or StablCal® Standard
Based on gravimetric TSS analysis with a correction factor procedure
Calibration Method: Turbidity Suspended Solids:Formazin or StablCal® Standard
Based on gravimetric TSS analysis with a correction factor procedure
Certifications: CE certified to EN 61326-1, EN 61326/A1, EN 61326/A2, EN 61010-1
Construction - Sensor Body (RD 240/260): Wiper
Sensor body: Silicon
Stainless steel or PVC
Construction - Sensor Body (RD 242/262): Wiper
Sensor body:Silicon
Stainless steel
Detection Limit: Turbidity

Suspended Solids 0.001 mg/L
Diameter Sensor: (diameter x length)
Immersion sensor: 60 mm x 315 mm (2.4 x)
Flow: 3 m/s (9.8 ft./s) maximum
Length: 200 mm
Lower Limit of Detection (LOD): Turbidity

Suspended Solids 0.001 NTU
Material: Optics Carrier and Sleeve: stainless steel 1.4571 or black PVC
Wiper Arm: stainless steel 1.4581; Wiper Blade: silicone (standard) Optional: Viton (LZX578); Wiper Shaft: stainless steel 1.4571
Threaded cable fitting: stainless steel 1.4305 or white PVC
Stainless steel can be susceptible to corrosion at chloride concentrations ≥ 500 mg/l.
Max. cable length Sensor-to-Controller: 100 m
Measuring Range Turbidity: Suspended Solids 0.001 - 4000 NTU
Mounting: Fixed to the rim of the tank
  Through sidewall of a pipeline using a ball valve; minimum pipe size (4 in.) in carbon or stainless steel
Operating temperature range: 0 - 40 °C
Parameter: obs
Pressure Range: Sample Pressure 6 bar (87 psi) maximum
Range: Turbidity
Suspended Solids 0.001 mg/L 50 g/L
Repeatability: Defined according to ISO/WD 13530. Turbidity Suspended Solids Less than3 %of reading (depends on the homogeneity of municipal activated sludge)
Repeatability Turbidity: Defined according to ISO/WD 13530. Suspended Solids. Less than 1 % of reading
Response time: Initial response in 1 second
Sample Temperature: 0 - 40°C (32 - 104°F)
Signal Average Time: Initial response in 1 s
Turbidity: Units of Measure Turbidity
Suspended Solids user selectable—NTU, FNU, or TE/F
Units: Units of Measure
Turbidity
Suspended Solids: User selectable—g/L, mg/L, ppm, or % solids
Weight: 1.38 kg
Weight Sensor: Immersion, stainless steel: 1.38 kg (3.0 lb.)
What's included?: Solitax hs-line sensor, Solitax User Manual, sc100 Controller, sc100 User Manual