Application - Filter Monitoring

Turbs

Monitoring turbidity of filter effluent is required for regulatory compliance in many countries and helps to assure that the final product is safe for public consumption.

In addition to meeting regulatory requirements, monitoring turbidity is also beneficial for optimizing filter performance, establishing filter backwash cycles, and detecting filter breakthrough.

Turbidity instrumentation is available to meet the unique needs of both conventional and membrane filtration facilities.
Filtertrak 660 sc Laser Nephelometer w/ SC200 Controller,  24 VDC, 1 Channel

FT660sc Laser Nephelometer

Product #: 2978400
FilterTrak Laser Nephelometer offers the best resolution in the market. Detects changes in turbidity as low as 0.0005 NTU. Meets all USEPA filtering monitoring requirements. Compatible with Hach Multi-Sensor, Multi-Parameter Digital Controllers, sensor can be used with Hach's new sc200 or sc1000 Digital Controllers. Includes Manual and Stablcal Turbidity Standards.

  • Lowest Limit of Detection in the Market
  • Meets All USEPA Filter Monitoring Requirements
  • Monitor, Optimize, and Report
  • Compatible with Hach Multi-Sensor, Multi-Parameter Digital Controllers
1720E Turbidimeter with SC200 Controller, 1 Channel

1720E Turbidimeter

Product #: 2978100
Meets and exceeds USEPA Method 180.1 for measuring turbidity for drinking water compliance. One controller accepts up to two plug and play sensors giving you two complete turbidimeters. Sensitive to fine changes in low level turbidity with a built-in bubble removal system. Built-in data logger stores up to 6 months of data. Versatile digital output-MODBUS. Two year warranty.

  • Accuracy
  • Simplicity
  • Data Collection and Display
  • USEPA Reporting
  • Experience
ULTRATURB plus sc 5M Cable & Auto clean, Low Range Process Turbidimeter

ULTRATURB

Product #: 2983400
Turbidities in the range of FNU (NTU) 0.0001-1,000 are measured and displayed alphanumerically using a controller. This high resolution facilitates precision differentiation, even for ultra clear liquids. A pulsed, long-life IR radiation source (LED) ensures that costs are minimized. Designed in accordance with DIN EN ISO 7027 and permanently calibrated before leaving the factory. All key data is set to practical standard values. The instruments are immediately ready for use after connection to the power supply and the supply of sample water. The measuring range and all data outputs are modified to suit requirements using menus on the controller. All optical and electronic assemblies are installed in housings that are physically very strong and proof against water jets. The measuring chamber also has automatic wiper cleaning.