2630020: Chlorine Standard Solution, 25-30 mg/L as Cl₂, pk/20 - 2 mL PourRite Ampules |
Solution |
2 - 500 µg/L ULR as Cl2 |
10014 DPD
|
|
View
|
Contact Hach
|
2834100: Potassium Iodide Swiftest Bulk Dispenser, with Potassium Iodide Refill Vial |
Swiftest |
0.005 - 5 mg/L Cl₂ |
AT1000 Total Chlorine, Forward Titration
|
|
|
Contact Hach
|
Swiftest |
0.003 - 5 mg/L Cl₂ |
AT1000 Amperometric Forward Titration Automatic Titrator Method
|
|
|
2630020: Chlorine Standard Solution, 25-30 mg/L as Cl₂, pk/20 - 2 mL PourRite Ampules |
Solution |
0.02 - 2.00 mg/L Cl₂ |
10060 DPD Rapid Liquid, Pour-Thru Cell
|
|
|
Contact Hach
|
2444800: Chlorine (Total) Reagent Set, HR Digital Titrator |
Digital Titrator |
2,000 - 70,000 mg/L CL₂ |
8209 Iodometric Method
|
|
View
|
OBSOLETE
|
1490932: Acetate Buffer Solution, pH 4.0, 100 mL |
Solution |
20 - 70,000 mg/L |
8209 WAH, Iodometric, Digital Titration
|
|
View
|
Contact Hach
|
2444800: Chlorine (Total) Reagent Set, HR Digital Titrator |
Digital Titrator |
1 - 400 mg/L Cl₂ |
8209 WAH, Iodometric, Digital Titration
|
|
View
|
OBSOLETE
|
1490932: Acetate Buffer Solution, pH 4.0, 100 mL |
Solution |
0.003 - 5 mg/L Cl₂ |
AT1000 Amperometric Forward Titration Automatic Titrator Method
|
|
|
Contact Hach
|
2155332: Buffer, Phosphate Type, pH 7, for Amperometric Chlorine, 100 mL MDB |
Solution |
0.005 - 5 mg/L Cl₂ |
AT1000 Amperometric BackwardTitration Automatic Titrator Method
|
|
|
Contact Hach
|
2444800: Chlorine (Total) Reagent Set, HR Digital Titrator |
Digital Titrator |
20 - 2,000 mg/L Cl₂ |
8209 Iodometric Method
|
|
View
|
OBSOLETE
|
2155332: Buffer, Phosphate Type, pH 7, for Amperometric Chlorine, 100 mL MDB |
Solution |
0.003 - 5 mg/L Cl₂ |
AT1000 Amperometric Forward Titration Automatic Titrator Method
|
|
|
Contact Hach
|
1490932: Acetate Buffer Solution, pH 4.0, 100 mL |
Solution |
20 - 2,000 mg/L Cl₂ |
8209 Iodometric Method
|
|
View
|
Contact Hach
|
34332: Potassium Iodide Solution, 30 g/L, 100 mL MDB |
Solution |
0.09 - 5.00 mg/L Cl₂ |
10101 DPD Test 'N Tube
|
|
|
Contact Hach
|
1490932: Acetate Buffer Solution, pH 4.0, 100 mL |
Solution |
0 - 10 mg/L Cl₂ |
8314 Amperometric Titration
|
|
|
Contact Hach
|
Solution |
0.005 - 5 mg/L Cl₂ |
AT1000 Amperometric BackwardTitration Automatic Titrator Method
|
|
|
Solution |
2,000 - 70,000 mg/L CL₂ |
8209 Iodometric Method
|
|
View
|
2321453: Iodine Standard Solution, 0.1 N (0.05 M), 1 L |
Solution |
5.1 - 5,000 µg/L as Total Chlorine |
4500 Standard Method Standard Method 4500 Cl C, Back Amperometric Titration
|
|
|
Contact Hach
|
1490932: Acetate Buffer Solution, pH 4.0, 100 mL |
Solution |
1 - 400 mg/L Cl₂ |
8209 WAH, Iodometric, Digital Titration
|
|
View
|
Contact Hach
|
34332: Potassium Iodide Solution, 30 g/L, 100 mL MDB |
Solution |
2 - 500 µg/L ULR as Cl2 |
10014 DPD
|
|
View
|
Contact Hach
|
2155353: Buffer, Phosphate Type, pH 7.0, 1 L |
Solution |
0.005 - 5 mg/L Cl₂ |
AT1000 Amperometric BackwardTitration Automatic Titrator Method
|
|
|
Contact Hach
|
Solution |
0.003 - 5 mg/L Cl₂ |
AT1000 Amperometric Forward Titration Automatic Titrator Method
|
|
|
1407728: DPD Free Chlorine Reagent Powder Pillows, 5 mL, PK/1000 |
Powder Pillows |
0 - 3.5 mg/L |
DPD
|
|
View
|
Contact Hach
|
34332: Potassium Iodide Solution, 30 g/L, 100 mL MDB |
Solution |
0.02 - 2.00 mg/L Cl₂ |
10060 DPD Rapid Liquid, Pour-Thru Cell
|
|
|
Contact Hach
|
2321453: Iodine Standard Solution, 0.1 N (0.05 M), 1 L |
Solution |
1.2 - 5,000 µg/L as Total Chlorine |
4500 Standard Method Standard Method 4500 Cl C, Back Amperometric Titration
|
|
|
Contact Hach
|
1490932: Acetate Buffer Solution, pH 4.0, 100 mL |
Solution |
3 - 100 µg/L Cl₂ |
AT1000 Total Chlorine, Diluted Titrant
|
|
|
Contact Hach
|
Solution |
0.005 - 5 mg/L Cl₂ |
AT1000 Total Chlorine, Forward Titration
|
|
|
608424: DPD Oxalate, 25 g |
Jar |
1.2 - 5,000 µg/L as Total Chlorine |
4500 Standard Method Standard Method 4500 Cl C, Back Amperometric Titration
|
|
|
Contact Hach
|
2563000: Chlorine Reagent Set (Total), Ultra Low Range DPD |
|
2 - 500 µg/L ULR as Cl2 |
10014 DPD
|
|
View
|
Contact Hach
|
2267301: Sodium Thiosulfate Digital Titrator Cartridge, 0.113 N |
Digital Titrator |
20 - 70,000 mg/L |
8209 WAH, Iodometric, Digital Titration
|
|
View
|
Contact Hach
|
2493023: Blanking Reagent for ULR Chlorine, 29 mL |
Solution |
2 - 500 µg/L ULR as Cl2 |
10014 DPD
|
|
View
|
Contact Hach
|
2267301: Sodium Thiosulfate Digital Titrator Cartridge, 0.113 N |
Digital Titrator |
20 - 2,000 mg/L Cl₂ |
8209 Iodometric Method
|
|
View
|
Contact Hach
|
35253: Sodium Thiosulfate Standard Solution, 0.025 N, 1 L |
Solution |
0 - 40,000 mg/L |
8161 WAH, Iodometric Buret Titration
|
|
|
Contact Hach
|
Solution |
0 - 400 mg/L |
8161
|
|
|
2440400: Chlorine Reagent Set, DPD Free and Total Chlorine, 25-mL sample |
|
0 - 3.5 mg/L |
DPD
|
|
View
|
Contact Hach
|
199953: Phenylarsine Oxide (PAO) Standard Solution, 0.00564 N, 1 L |
Solution |
0 - 10 mg/L Cl₂ |
8314 Amperometric Titration
|
|
|
Contact Hach
|
2438600: Chlorine (Total) Reagent Set for CN-65 Test Kit |
|
1 - 20 mg/L |
Thiosulfate
|
|
View
|
Contact Hach
|
107799: Potassium Iodide Powder Pillows, PK/100 |
Powder Pillows |
0 - 10 mg/L Cl₂ |
8314 Amperometric Titration
|
|
|
Contact Hach
|
Powder Pillows |
0 - 40,000 mg/L |
8161 WAH, Iodometric Buret Titration
|
|
|
2438600: Chlorine (Total) Reagent Set for CN-65 Test Kit |
|
0.2 - 4 mg/L |
Thiosulfate
|
|
View
|
Contact Hach
|
2437700: Chlorine (Total) Reagent Set for CN-21P |
|
10 - 200 mg/L |
Thiosulfate
|
|
View
|
Contact Hach
|
107799: Potassium Iodide Powder Pillows, PK/100 |
Powder Pillows |
0 - 400 mg/L |
8161
|
|
|
Contact Hach
|
2409101: Sodium Thiosulfate Digital Titrator Cartridge, Stabilized, 0.02256 N |
Digital Titrator |
2,000 - 70,000 mg/L CL₂ |
8209 Iodometric Method
|
|
View
|
Contact Hach
|
Digital Titrator |
1 - 400 mg/L Cl₂ |
8209 WAH, Iodometric, Digital Titration
|
|
View
|
107799: Potassium Iodide Powder Pillows, PK/100 |
Powder Pillows |
2,000 - 70,000 mg/L CL₂ |
8209 Iodometric Method
|
|
View
|
Contact Hach
|
2409101: Sodium Thiosulfate Digital Titrator Cartridge, Stabilized, 0.02256 N |
Digital Titrator |
20 - 2,000 mg/L Cl₂ |
8209 Iodometric Method
|
|
View
|
Contact Hach
|
Digital Titrator |
20 - 70,000 mg/L |
8209 WAH, Iodometric, Digital Titration
|
|
View
|
107799: Potassium Iodide Powder Pillows, PK/100 |
Powder Pillows |
1 - 400 mg/L Cl₂ |
8209 WAH, Iodometric, Digital Titration
|
|
View
|
Contact Hach
|
2408549: Sodium Thiosulfate Standard Solution, Stabilized, 0.00246 N, 500 mL |
Solution |
1 - 20 mg/L |
Thiosulfate
|
|
View
|
Contact Hach
|
Solution |
0.2 - 4 mg/L |
Thiosulfate
|
|
View
|
107799: Potassium Iodide Powder Pillows, PK/100 |
Powder Pillows |
20 - 2,000 mg/L Cl₂ |
8209 Iodometric Method
|
|
View
|
Contact Hach
|