Chemistries                 0800 50 55 66

HQ30d Meter, PHC101 Rugged pH Probe with 5 meter cable

OBSOLETE ITEM

HQ30d Meter, PHC101 Rugged pH Probe with 5 meter cable
Product #: HQ30D53115000

OBSOLETE ITEM

Guided Calibrations

All Hach HQd Digital Meters provide an intuitive user interface with guided calibration and check standard routines to reduce calibration errors and simplify operation. Calibration status indicator and custom calibration alerts ensure accurate results.

Traceability and Reporting

HQd meters record probe serial numbers, current calibration data, user ID, sample ID, time, and date automatically in the data log. Each measurement can be linked to sample ID, user ID, probe serial number, and more for complete traceability and regulator

Easy to Use in the Field

All connections between the meter and the probe are secure and waterproof. Connectors can be color-coded for quick identification. Information is clearly displayed on the one screen with back light for low light conditions. Display results can be enlarged.

Error-free O2 results without calibration or replacing the electrolyte

Rugged and waterproof meter design provides worry-free, reliable operation in field environments. All connections between the meter and the probe are secure. Connectors can be color-coded for quick identification. Information is clearly displayed on the one screen with back light for low light conditions. Display results can be enlarged.

Full GLP data management

Package content includes everything you need to start testing. Details below

What's included?

Meter package includes HQ30D Portable Meter; 4 AA batteries, PHC101 Rugged Field Gel pH Electrode, 5 m cable; quick-start guide and user manuals.

Specifications

AC and USB Operation: Optional
Automatic Buffer Recognition: Yes
Backlight:
Barometric Pressure Measurement: For automatic compensation of DO when using an LDO or LBOD probe
BOD5/CBOD resolution: Available when used with Hach WIMS BOD Manager software
Calibration: Demal (1D/ 0.1D/ 0.01D);
Molar (0.1M/ 0.01M/0.001M);
NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm);
Standard sea water;
User defined
Calibration Intervals/Alerts/Reminder: Off, selectable from 2 hours to 7 days
Compliance Certifications: CE
Conductivity measurement: 5 different stability modes
Conductivity measurement: Temperature correction: None; Linear; NaCl Non-Linear Natural Water.
Conductivity Measurement Range: 0.01 µS/cm to 200 mS/cm
Conductivity resolution: 0.01 µS/cm with 2 digits
Contents: No
Custom Calibration Standards: User-defined standard sets
Data Export: Download via USB connection to PC or flash memory device.
Automatically transfer entire data log or as readings are taken.
Data Memory: 500 results
Data Storage: GLP/ISO compliant reading data stored with calibration details.
Calibration details and check standard readings documented in data log.
Automatically store in "press to read" mode and interval measurement mode.
Manually store in "continous read" mode.
Digital (intelligent) electrode inputs: 1 channel
Display: Display readings from one or two probes

Simultaneous readings from two probes (HQ440d only)

pH: pH, mV, temperature

Conductivity: Conductivity, TDS, salinity, resistivity, temperature

LDO: dissolved oxygen, pressure, temperature

LBOD: dissolved oxygen, pressure, temperature

ORP/Redox: mV, temperature

Sodium: Sodium, mV, temperature
Display Lock Function: Continuous measurement or "press to read" mode available with averaging function for LDO measurement.
Display Type: 240 x 160 pixel LCD with backlight illumination
DO Measurement Range: 0.1 - 20.0 mg/L (ppm) 1 - 200% saturation
DO Resolution: 0.1
DO sensor calibration: * 100% (water-saturated air (100%) calibration
* 100% with 0 (water-saturated air (100%) calibration with 0 point
* mg/L (calibration with a specified dissolved oxygen concentration (mg/L) solution)
* mg/L with 0 (calibration with a specified dissolved oxygen concentration (mg/L) solution with 0 point)
* Factory (calibration with the default LDO calibration)
Electrode stand:
GLP Features:
Inputs: 1
Instrument: Portable
Interface Languages: 13**
IP Rating: IP67
ISE Direct Measurement Range: Yes
ISE Electrode Calibration: Electrode specific - see electrode user instructions
Kit?: Yes
Languages: English, French, German, Italian, Spanish, Danish, Dutch, Polish, Portuguese, Turkish, Sweedsh, Czech, Russian
Measurement method: Probe specific programmed method settings
Model: HQ30D – Multi/1 Channel
mV Measurement at Stable Reading: 5 (auto) stabilization settings
mV Measurement Range: -1500 - 1500 mV
mV Resolution: 0.1 mV
Needed Cable Length: 5
Operating Error Messages: Text messages displayed
Operating Humidity: 90 % relative humidity (non-condensing)
Operating Interface: Keypad
Operating Temperature: 0 - 60 °C (32 - 140 °F)
ORP Electrode Calibration: Predefined ORP standards (including Zobell's solution)
Parameter: pH, mV, ISE, DO, Conductivity, TDS, Salinity, Resistivity, ORP, Temp
Parameters: pH
NA
NA
PC Data Transfer Software: Included
pH Buffer Sets: IUPAC standards
(DIN 19266) or Technical buffer (DIN 19267) or 4-7-10 series or user defined
pH Electrode calibration: 1 - 3 Calibration points
Calibration summary data logged and displayed
pH Measurement Range: 0 - 14 pH
pH Resolution: Selectable:
0.001/0.01/0.1 pH
Printer: Optional accessory
Probes included: PHC10105
Probe Type: Standard
Resolution: 0.1/ 0.01/ 0.001
Salinity Measurement Range: 0 - 42 (ppt) (‰)
Salinity Resolution: 0.01 (ppt) (‰)
Sensor A: PHC10105 (5 m rugged)
Sensor B: NA
Sensor C: NA
Sensors: Sensor A: PHC10105
Sensor B: NA
Sensor C:
TDS Measurement Range: 0.00 mg/L - 50.0 g/L NaCl
TDS Resolution: 0.01 mg/L up - 0.1 g/L upon measuring range
Temperature Compensation: Automatic Temperature compensation for pH
  Automatic Temperature compensation for pH
Temperature Measurement: °C or °F
Temperature Resolution: 0.1
Type of measurement: Field Measurements
Warranty: 2 years
  36 months
Weight: 335 g (0.75 lb) without batteries; 430 g (0.95 lb) with
What's included?: Meter package includes HQ30D Portable Meter; 4 AA batteries, PHC101 Rugged Field Gel pH Electrode, 5 m cable; quick-start guide and user manuals.