Accuracy:
                                            
                                            
                                        
									    ± 4% of reading ± 0.1 mg/L NO₃-N from 0.05 - 22 mg/L,
± 5% of reading ± 0.1 mg/L NO₃-N from 22 - 50 mg/L
                                    
                                
    						
								
                                    
                                        
                                            
                                                Altitude:
                                            
                                            
                                        
									    2000 m (6562 ft) maximum
                                    
                                
    						
								
                                    
                                        
                                            
                                                Ambient Temperature:
                                            
                                            
                                        
									    2 - 40 °C, 95% relative humidity, non-condensing
                                    
                                
    						
								
                                    
                                        
                                            
                                                Cable Length:
                                            
                                            
                                        
									    10 m
Extension cables are available: 5, 10, 15, 20, 30 and 50 m. The maximum cable length is 60 m.
                                    
                                
    						
								
                                    
                                        
                                            
                                                Certifications:
                                            
                                            
                                        
									    CE, CMIM, UKCA, FCC, and ISED approved
                                    
                                
    						
								
                                    
                                        
                                            
                                                Controller Compatibility:
                                            
                                            
                                        
									    SC200, SC1000, SC4500
                                    
                                
    						
								
                                    
                                        
                                            
                                                Dimensions:
                                            
                                            
                                        
									    70 x 402 mm approximately
                                    
                                
    						
								
                                    
                                        
                                            
                                                Indoor/Outdoor:
                                            
                                            
                                        
									    Outdoor
                                    
                                
    						
								
                                    
                                        
                                            
                                                IP Rating:
                                            
                                            
                                        
									    IP68
                                    
                                
    						
								
                                    
                                        
                                            
                                                Lower Limit of Detection (LOD):
                                            
                                            
                                        
									    0.05 mg/L NO₃-N
                                    
                                
    						
								
                                    
                                        
                                            
                                                Material:
                                            
                                            
                                        
									    Sensor enclosure: 1.4571 Stainless Steel
Enclosure seals: Silicone
Wiper axle, arm (5 mm) and wiper blade carrier (1 mm and 2 mm): 1.4571 Stainless Steel
Wiper blade: Silicone
Measuring window: Quartz glass
Sensor cable: Polyurethane (PUR)
Cable gland: 1.4571 Stainless Steel
Seal cable gland: Silicone HT
                                    
                                
    						
								
                                    
                                        
                                            
                                                Measurement method:
                                            
                                            
                                        
									    UV Absorption, sludge compensated, 2-channel beam path
                                    
                                
    						
								
                                    
                                        
                                            
                                                Measuring Interval:
                                            
                                            
                                        
									    15, 30 seconds, 1, 5, 10, 30 minutes
                                    
                                
    						
								
                                    
                                        
                                            
                                                Measuring Principle:
                                            
                                            
                                        
									    UV absorption measurement, reagent-free
                                    
                                
    						
								
                                    
                                        
                                            
                                                Model:
                                            
                                            
                                        
									    NT3100sc
                                    
                                
    						
								
                                    
                                        
                                            
                                                Over voltage category:
                                            
                                            
                                        
									    II
                                    
                                
    						
								
                                    
                                        
                                            
                                                Parameter:
                                            
                                            
                                        
									    Nitrate
                                    
                                
    						
								
                                    
                                        
                                            
                                                Path Length:
                                            
                                            
                                        
									    2 mm
                                    
                                
    						
								
                                    
                                        
                                            
                                                Pollution Degree:
                                            
                                            
                                        
									    2
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power Consumption:
                                            
                                            
                                        
									    9 W
                                    
                                
    						
								
                                    
                                        
                                            
                                                Pressure Range:
                                            
                                            
                                        
									    Sensor pressure limit: 0.5 bar
                                    
                                
    						
								
                                    
                                        
                                            
                                                Process Connection:
                                            
                                            
                                        
									    Immersion directly in media
Bypass with Flow Through Unit
Sedimenter
                                    
                                
    						
								
                                    
                                        
                                            
                                                Range:
                                            
                                            
                                        
									    0.05 - 50 mg/L NO₃-N
                                    
                                
    						
								
                                    
                                        
                                            
                                                Resolution:
                                            
                                            
                                        
									    0.01 - 999.9
                                    
                                
    						
								
                                    
                                        
                                            
                                                Response time:
                                            
                                            
                                        
									    T100: 1 minute
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Temperature:
                                            
                                            
                                        
									    2 - 40 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Signal Average Time:
                                            
                                            
                                        
									    1 to 12 measurements
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sludge Compensation:
                                            
                                            
                                        
									    Yes
                                    
                                
    						
								
                                    
                                        
                                            
                                                Units:
                                            
                                            
                                        
									    mg/L, ppm
                                    
                                
    						
								
                                    
                                        
                                            
                                                Warranty:
                                            
                                            
                                        
									    12 months
                                    
                                
    						
								
                                    
                                        
                                            
                                                Weight:
                                            
                                            
                                        
									    4.8 kg with 10 m cable
                                    
                                
    						
								
                                    
                                        
                                            
                                                What's included?:
                                            
                                            
                                        
									    Sensor with  cable set, set of wipers, user manual