Accuracy:
The greater of ±1% of reading, or ±0.03 ppb, or ±1 Pa (Membrane 2956A)
Accuracy 2:
The greater of ±1% of reading, or ±0.09 ppb, or ±6 Pa (Membrane 2952A)
Accuracy 3:
The greater of ±1% of reading, or ±1 ppb, or ±50 Pa (Membrane 2995A)
Accuracy 4:
The greater of ±1% of reading, or ±10 ppb, or ±1 kPa (Membrane 29015A)
Ambient Temperature:
-5 - 100 °C (23 - 212 °F)
Application:
Corrosion rate
Certifications:
IP68 / NEMA4
Flow Rate:
Typical Flow Rate
Membrane 2956A: 50 - 220 mL/min
Membrane 2952A: 40 - 200 mL/min
Membrane 2995A: 20 - 70 mL/min
Membrane 29015A: 20 - 40 mL/min
Protection Class:
IP68 / NEMA4
Purge connection:
None
Radiation Resistance Level:
Membrane 2956A: 2x104 rad
Membrane 2952A: 108 rad
Membrane 2995A: 108 rad
Membrane 29015A: N/A
Range:
Range at 25 °C
Membrane 2956A: 0 - 75 ppb or 0 Pa - 5 kPa
Membrane 2952A: 0 - 300 ppb or 0 Pa - 20 kPa
Membrane 2995A: 0 - 3200 ppb or 0 Pa - 200 kPa
Membrane 29015A: 0 ppb - 32 ppm or 0 - 2000 kPa
Sample Pressure:
0 - 100 bar
Temperature Range:
Accurate from -5 - 50 °C (23 - 122 °F)
Resistant - temperature from -5 - 100 °C (23 - 212 °F)
Warranty:
6 months
Weight:
140 - 700 g, depending on the construction material
What's included?:
Sensor only.
Controller, sensor cable, flow-chamber or process connection must be ordered separately.