Prices Online Include GST      0800 50 55 66

Phosphax sc LR Phosphate analyser, 0.015-2 mg/L PO₄-P, outdoor, 1-channel, 115-230 VAC

Phosphax sc LR Phosphate analyser, 0.015-2 mg/L PO₄-P, outdoor, 1-channel, 115-230 VAC
Product #: LXV422.99.33001
Unit Price Contact Hach

Confidence in low range measurement values

The Phosphax sc LR features a new photometer with glass cuvette that results in high stability in low range measurement giving you confidence in your measurement values.

Ensure compliance and lower plant-operating costs

The Phosphax sc LR features a new yellow method with split-reagent dosing, and a new photometer with twice the path length of the Phosphax sc. These features result in high accuracy in low range measurement that help you do just enough treatment to stay compliant and lower plant operating costs at the same time.

Generate actionable insights from measurement data

The Phosphax sc LR is Smart Monitoring enabled so you can leverage Hach to collect, manage and analyse data from your instrument.

What's included?

Phosphax sc LR Phosphate Analyser, 3 month supply of all necessary consumables at 5 minute cycle time, user manuals

Specifications

Accuracy: Using standard solutions: 2 % + 0.015 mg/L
Cable Length: 2 m from edge of enclosure
Channels: 1
Data Transfer: SC standard
Dimensions (H x W x D): 720 mm x 540 mm x 390 mm
Enclosure Rating: IP55
Flow: 1.0 - 20.0 L/h
Housing Type: Outdoor
Indoor/Outdoor: Outdoor
Lower Limit of Detection (LOD): Using standard solutions: 0.015 mg/L
Material: ASA/PC UV-resistant
Measurement method: Two-beam photometer (yellow method)
Measuring Interval: 10 - 120 min
Operating temperature range: -20 - 40 °C, 95 % relative humidity (non-condensing, non-corrosive)
Outputs: Relay, analogue outputs, network interface through SC controller
Parameter: Ortho-Phosphate
Permissible Chloride Range: Max Cl- concentration: 5000 mg/L
pH Range: 5 - 9 pH
Power requirements (Hz): 50/60 Hz
Power Requirements (Voltage): 115 - 230 V AC, powered by Power Box or SC Controller
Power supply: 115 - 230 V AC, powered by Power Box or SC Controller
Pressure Range: -30 - 50 mbar with continous sample preparation; at overflow vessel
Range: 0.015 - 2 mg/L PO₄-P
Reproducibility: 0.7 % + 0.005 mg/L
Response Time: 10 min
Sample Level: Level of liquid in a basin with filtration probe must be below analyser
Sample Quality: Ultra filtrated or comparable
Sample Temperature: 4 - 45 °C
Storage conditions: -20 - 60 °C; 95 % relative humidity, non-condensing
Warranty: 12 months
Weight: Without sample preparation system and without chemicals: 31 kg
What's included?: Phosphax sc LR Phosphate Analyser, 3 month supply of all necessary consumables at 5 minute cycle time, user manuals