Chemistries                 0800 50 55 66

Solitax t-line sc Turbidity Immersion Probe with Wiper, including a SC200 Controller, PVC

OBSOLETE ITEM

Solitax t-line sc Turbidity Immersion Probe with Wiper, including a SC200 Controller, PVC
Product #: 2983400

OBSOLETE ITEM

No Calibration for Turbidity Measurement

All Solitax sc probes are factory calibrated in conformity with DIN EN ISO 7027 for long-term calibration stability. A correction factor replaces the time consuming multipoint on-site calibrations.

Self-cleaning Wiper Prevents Erroneous Values

The SOLITAX sc sensor's self-cleaning wiper prevents erroneous values and maintenance problems by preventing biological growth. Gas bubbles in the sample do not interfere with the measurement.

Combinable with probes for oxygen, pH, nitrate, etc.

Any combination with other parameters helps improve process control and reduce treatment costs

Fully Serviceable Sensors

Conventional Turbidity and Suspended Solids sensors are potted and discarded when they no longer function. Solitax sc sensors are serviceable so that the useful life of the sensor, in many cases, is doubled.

What's included?

Turbidity probe, controller, user manual

Specifications

Accuracy: Turbidity up to 1000 NTU;
without calibration < 5% of the measured value ±0.01 NTU;
with calibration < 1% of the measured value ±0.01 NTU;
Automatic Wiper: Yes
Body Material: PVC
Cable Length: 10 m (optional extension cables available)
Calibration Method: Turbidity: Formazin or STABLCAL Standard (at 800 NTU); Suspended Solids: Sample specific, based on gravimetric TSS analysis with a correction factor procedure;
Certifications: CE
Configurations: Includes SC200 Controller
Controller: SC200
Diameter Sensor: 60 mm
Flow: Max. 3 m/s (the presence of air bubbles affects the measurement)
Includes: Turbidity probe, controller, user manual
Installation style: Tank Immersion
Length: 200 mm
Maintenance Interval: 1 h/month
Material: Optics Carrier and Sleeve: PVC black; Wiper Arm: stainless steel 1.4581; Wiper Rubber: silicone rubber (standard) Optional: FKM/FPM (LZX578); Wiper Shaft: stainless steel 1.4571;
Max. cable length Sensor-to-Controller: 100 m
Measuring Principle: Infrared Duo scattered light technique for color-independent turbidity measurement, Turbidity in accordance with DIN EN ISO 7027 / TS equivalent DIN 38414
Model: Solitax t-line sc
Mounting: Immersion
Operating temperature range: 0 - 40 °C
Parameter: Turbidity
Pressure Range: PVC: < 1 bar or < 10 m
Range: Turbidity: 0.001 - 4000 NTU
Repeatability: Turbidity: < 1 %
Response Time T90: 1 - 300 s adjustable
Warranty: 12 months
Weight: 0.52 kg
What's included?: Turbidity probe, controller, user manual